The service pack must be installed with local administrator rights. Die Installation des Service Packs muss mit lokalen Administratorrechten durchgeführt werden. Prerequisite for service pack 2: An existing installation of Smap3D Plant Design 2026 release version or Smap3D Plant Design 2026 service pack 1 Voraussetzung für Service Pack 2: Eine vorhandene Installation der Smap3D Plant Design 2026 Release Version oder Smap3D Plant Design 2026 Service Pack 1 Supported CAD systems: Unterstützte CAD-Systeme: Solid Edge 2025 or 2026 with latest update Solid Edge 2025 oder 2026 mit dem neuesten Update/Service Pack SOLIDWORKS 2025 or 2026 with latest service pack SOLIDWORKS 2025 oder 2026 mit dem neuesten Service Pack Autodesk Inventor 2025 with latest service pack Autodesk Inventor 2025 mit dem neuesten Service Pack or / oder Autodesk Inventor 2026 with latest service pack, but only if Autodesk Apprentice Server 2026 was installed correctly before installing the release version of Smap3D Plant Design 2026 (using the full installation package). Autodesk Inventor 2026 mit dem neuesten Service Pack, jedoch nur, wenn Autodesk Apprentice Server 2026 vor der Installation von Smap3D Plant Design 2026 release version (unter Verwendung des vollständigen Installationspakets) korrekt installiert wurde. or / oder Autodesk Inventor 2027 with latest service pack, but only if Autodesk Apprentice Server 2027 was installed correctly before installing Smap3D Plant Design 2026 Service Pack 1 (using the full installation package). Autodesk Inventor 2027 mit dem neuesten Service Pack, jedoch nur, wenn Autodesk Apprentice Server 2027 vor der Installation von Smap3D Plant Design 2026 Service Pack 1 (unter Verwendung des vollständigen Installationspakets) korrekt installiert wurde. ! IMPORTANT NOTE: This service pack updates ONLY workstations with an existing Smap3D Plant Design 2026 installation (including License Client Manager). This Service Pack installation file (.EXE) is NOT suitable for new installations on computers that do NOT have an existing Smap3D Plant Design 2026 installation. ! WICHTIGER HINWEIS: Dieses Service Pack aktualisiert NUR Arbeitsplätze mit bestehender Smap3D Plant Design 2026 Installation (inklusive License Client Manager). Diese Service Pack Installationsdatei (.EXE) ist NICHT geeignet für die Neu-Installation von Computern OHNE eine bestehende Smap3D Plant Design 2026 Installation. ========================================================================== Contents SP2 (24.26.200.21): ========================================================================== Service pack 2 for Smap3D Plant Design 2026 includes: Smap3D Parts Management 22.26.300.1 (SP3) P&ID 26.0.3.8 Electrical 26.0.3.8 Smap3D Plant Design applications 24.26.200.21 ScanToCAD 2026.0.64 License Client Manager 11.26.0.15 *** ENHANCEMENTS *** Piping 43801 Pipe Specification Editor- new function to switch Part Provider for a pipe specification 45981 Pipe Specification Editor - Undo and Redo buttons now have sub-menus with individual steps. 45984 Pipe Specification Editor - Range changes in Pipe Specification Editor no longer influence the dirty flag of opened pipe specification 46737 Pipe Specification Editor - Better handling of missing .pssx file 47305 Piping - New context menu function "Delete Piping QP information from Component(s)" Isometric 47048 Isometric options resize now causing more controls resize with the form 47051 Isometric/PCFExport/PipeFabConnect Step 2 - better toolbars 47073 Isometric/PCFExport/PipeFabConnect Step 2 - keyboard shortcuts and tooltips for disabled buttons are displayed 47075 Isometric/PCFExport/PipeFabConnect Step 1 - has now a context menu for history links 47076 Isometric Step 4 - now uses colors in log messages *** CHANGES *** GENERAL 46608 ISOGEN updated to version 10.0.0.61 Piping 47235 Pipe Specification Editor - Options for Diameters in NPS 3 decimal places precision 46610 Piping - Different names of columns in Non-unique dialogue were synchronized *** REPAIRED BUGS *** GENERAL 47241 Translated trace log dialogue (form showing the tracelog) P&ID / Electrical SPID-1100 Fixed - System Error code 126 in PID appears as soon as there there is a list page in a project SPID-1098 Fixed - ConnectionSize values are NOT written to every symbol that is inserted FIRST into a project when Accessory mapping is active SPID-1097 Fixed - Automatic update of symbol datafields linked to DB record, or command update reference does NOT work SPID-1086 Fixed - Crash of "Symbol library editor" (from tool "edit symbol data fields") after task has finished Piping 46026 Pipe Specification Editor - Minor graphical fixes in some localizations of Pipe Specification Editor's ribbon bar 47097 Piping - Place component pattern is slower compared to the previous version 47100 Piping - Concentric reducers are sometimes inserted in the wrong orientation 47240 Piping - Wrong values of custom properties and wrong set of properties written to tube during generation or recalculate in Inventor Isometric 44291 Fixed - wrong caps orientation in some isometric drawings 46367 Fixed - HIGHEST_WELD_NUMBER is now preserved in Isometric/PCFExport in case several pipelines are merged to one in output PCF 47132 Fixed - problem backward compatibility of global rules setting files in Isometric 47138 Fixed - disappearing text-boxes (on left click) in Formula editor in Isometric/PCFExport/Bending/PipeFabConnect 47170 Fixed - problem with visibility of floating dock-able windows in Isometric/PCFExport/PipeFabConnect 47277 Fixed - Formula editor in Isometric (and similar applications) did not allows direct edit of feature names ========================================================================== Contents SP1 (24.26.100.46): ========================================================================== Service pack 1 for Smap3D Plant Design 2026 includes: Smap3D Parts Management 22.26.200.16 (SP2) P&ID 25.0.4.82 Electrical 25.0.4.82 Smap3D Plant Design applications 24.26.100.46 ScanToCAD 2026.0.64 License Client Manager 11.26.0.15 *** ENHANCEMENTS *** Piping 13794 Pipe Specification common settings support sorting and custom ordering of Keynames 34215 New options 'Size for preview pipe' and 'Shape for preview pipe' have been added to the Pipe Specification Editor 45931 New context menu in the VC section of the Piping application allows you to open the assigned pipe specification in the Pipe Specification Editor when a piping path is selected Isometric 44744 Some of Isometrics's settings pages use larger controls (style selection, etc.), including in Step 3 46728 On the 'Output Mapping' tab under 'Isometric Options,' you can now select from existing feature names Bending Simulation 45932 Bending Simulation now allows you to select the pipes before running the simulation *** CHANGES *** GENERAL The following Smap3D Plant Design applications have been fully converted to the DevExpress Desktop UI Components programming controls: - Pipe Specification Editor - common settings - Isometric - PCF Export - Bending Simulation - PipeFab Connect Piping 25208 Pipe specification common settings validation – mandatory column must contain at least one value 27708 Pipe specification common settings validation – tooltips added for inactive controls 46985 Pipe specification common settings – only one of 'Reduction' or 'Is Pipe' can be selected at a time 47025 Pipe Specification Editor - decimal places in Insulation tab are enhanced to 3 for NPS P&ID To-Do list 45556 New option has been added that Updates 3D objects in the pipeline while the 'Update info in CAD' command is being executed for pipelines 46736 Symbol update with replacement is only possible if the 3D occurrence is included in the active assembly *** REPAIRED BUGS *** Database Administrator 46621 Fixed - The 'Werkstoff' characteristic was replaced by 'Material' again in DE language 46806 Fixed - Enable the entry of multiple row values in the grids/tables in the Database Administrator P&ID / Electrical SPID-1059 Fixed - Scrolling/Paning of larger P&IDs is slow and 'blinking' SPID-1081 Fixed - Strange Copy and Paste behavior for line datafields values Piping 46609 Fixed - Preview is active at start of the Non-unique dialogue 46708 Fixed - Adapt component command (for single orbital weld component) not longer allow entering values by typing 46783 Fixed - Piping command - Flip component does not work 46784 Fixed - Flow direction design check 'Show details / Flow check result' window has wrong behavior of 'Cancel' button P&ID To-Do list 46739 Fixed - Symbol replacement fails when symbol is not placed on a pipeline 46800 Fixed - ToDoList - wrong flow direction calculation 46878 Fixed - Error occurs when trying to update symbol after it was manually deleted from assembly 46918 Fixed - XML PID does not work properly with non unique names in it